dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6
dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6
dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6

dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6

$1,000.00 - 10,000.00/Set
Place of Origin
Jiangsu, China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

Place of Origin
Jiangsu, China
Power Source
Electricity
Shelf Life
2 years
Type
Doppler Ultrasound Equipment
Instrument classification
Class II
monitor
17 TFT
Brand Name
Dawei
Material
Metal, Plastic
Model Number
DW-T6(DW-C900)
DVD-RW
support
equipment
color doppler
probe connector
3
Quality Certification
ce
usb ports
4
Safety standard
GB15979-2002
standard
3.5MHz convex probe
grey scale
256
Warranty
2 years
Supply Ability
200 Set/Sets per Month
Video printer
optional
Packaging Details
wooden carton package package size: 97*68*141cm G.W.: 80kgs 4D trolley ultrasound machine
blood flow image
support
After-sale Service
Online technical support
Port
Shanghai port

Product Details

 

 

 

Product Description

dual screen ultrasound machine&trolley color doppler ultrasound machine &real time 4D ultrasound

 

 

 

 

  Mode of display 

    Black-and-white image: B, 2B, 4B, right/left B|M, B|D, right/left PW(D), top/down PW(D), M, B mode local amplification, linear probe trapezoidal imaging, 3D reconstruction/real-time 3D imaging

  Blood flow images: spectrum: B/BC, BC/B, B/D, B/C/D  CFM: B|C|D, B|C|M, B|C double real-time, PW(D)(D), CFM, CPA, CW

   Color Doppler:

    Mode of display: energy, velocity, variance (in support of velocity variance), frequency, gain

   Display control: the size and position of the sampling box are adjustable, the emitting angle of the linear probe is adjustable.

    Spectral Doppler:

  Sampling volume and position are adjustable PW(D) tracing supports maximum and average velocity. The threshold of the maximum velocity is adjustable. Scanning scope: above base-line, below base-line and entire scanning. PW(D) sound can be turned on or off, and can be regulated in volume. Velocity measuring: in support of maximum and minimum velocity

  Parameters for control of blood flow color images: Doppler frequency, position and size of sampling box, base line, color gain, deflection angle, wall filter, accumulative number of times, etc.

  Color depth of display 

   Continuously adjustable

  Focusing

  Electronic focusing + sound lens focusing

  Emission involves single focus, double focuses, triple focuses, and quadruple focuses    Continuously dynamic focusing in receiving

 dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6

 Formation of digital beam 

Continuously dynamic focusing

 Dynamic aperture diameter

 Weighted sum of reception delay

 In support of semi-moment scanning, and ±10° linear reception deflection angle

  Multi-beam processing

  Signal processing/Doppler sound

   Dynamic wave filtering

 Quadrature demodulation

  Total gain control

 Composite gain technology: 8-section TGC and D-AGC.

  Low-pass filter

  Secondary sampling

  Acoustic output adjustment

  Adjustable Doppler stereophonic acoustic output

dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6 

Image processing  

Dynamic scope variation and logarithmic compaction

 Time filtering

 Space filtering

 Frame average

 Fringe enhancement

 Gray scale variation

  B|M- or M-mode scanning speed

 Linear density control

 Scanning angle/width control

  Image optimization

 Upward and downward Image flipping

  Multi-angle image rotation

 Options for color gray-scale bar inversion

 Combined processing of tissue and flow images

Resolution of black-and-white images: 1024×768×8 bits (256 gray-scale)

 Resolution of color images: 8 bit×8 bit×8 bit color coding

  Selection of specific images

Optimized items are available to choose from

  Basic measuring and calculating functions

  2D normal measurement: distances, angle, perimeter, area (ellipse and locus methods), volume, volume – 3-line method (length, width, height), histogram, cross-section chart

 Basic M-Mode measurement: time, distance, heart rate, valve rate

  Obstetric measurement 

   With 4 varieties of obstetric databases for reckoning gestation age 

3 non-editable versions: Asian, European and American, plus 1 editable version: user-customized. 

The gestation age can be reckoned by the information in each version on gestational sac diameter, crown-rump length, biparietal diameter, head circumference, abdominal circumference, femur length, humerus length, abdominal transversal diameter, length of vertebrae, occipital-frontal diameter, cerebellum diameter, fibula length, radius length, Cisterna Magna, inner orbital diameter, output orbital diameter, amniotic fluid index, fetal heart rate, nuchal transparency, distance and area, etc. 

 Obstetric report

  Measurement and calculation of amniotic fluid index (AFI) 

   Ratio calculation (BPD/OFD, FL/AC, FL/BPD and HC/AC)

  Fetus weight estimation

   Reckoning the gestation age and EDD by LMP and BBT

   Fetal biophysical score

  Fetal growth curve

  Andrology measurement and calculation

  Measurement and calculation of prostate and testis

  Calculation of predicted prostatic specific antigen (PPSA) and Prostatic Specific Antigen density (PSAD).

  Gynaecology measurement

  Measurement and calculation of the uterus, left ovarium, right ovarium, left folliculus, right folliculus, etc.

  Urology measurement and calculation

 Detection and calculation of the left kidney, right kidney, bladder, residual urinal vol, etc.

  Vessel measurement and calculation

Measurement and calculation of area stenosis rate and vascular stenosis rate.

  Multi-fetus detection and measurement

 Detection of multiple fetuses

  Small parts detection and calculation   

 Detection and calculation of thyroid, galactophore, masses, etc. 

  Orthopedic surgery measurement

Detection of the left and right hip joint

 

dual screen ultrasound machine &trolley color doppler ultrasound machine &real time 4D ultrasound DW-T6 

Cardiac detection and calculation functions

 Cardiology measurement software package—contains features of analyzing and measuring aorta, mitral valve, (left/right) ventricles, etc. 

  Area stenosis percentage (% area sten), tube diameter stenosis percentage (% Diam Sten) 

  Body surface area (BSA)

  Body mark   

    In terms of bodily function, an body mark database is divided into several parts: abdomen, andrology, cardiology, gynecology, musculoskeletal, obstetrics, pediatric, small parts, urology, etc.

  Screen-displayed information 

 Probe conditions, mode of display, depth, focus, dynamic range, body marks, probe position marker, acoustic output, patient conditions, name of medical agency, measured value, time and date, scale, scanning direction, gray-scale curve, current working frequency of the probe, frame frequency, B-Mode total gains, C-Mode total gains, Mode-D total gains, menu, annotations, gray-scale belt, puncture guide line, TI (thermal index), MI (mechanical index)   

 Storage  

 Probe parameter storage 

 Image storage

Cine loop storage

 Measurement results storage

  Report storage

  Cine loop

 Automatic cine-loop

Manual cine-loop

   Cine-loop speed setting 

  Cine-loop search

 Frame-by-frame forward/backward cine-loop

  Digital ultrasonic working station (optional) 

 General report

Obstetric report

 Andrology report

 Gynaecology report

 Urology report

 Blood vessel report

 Small parts report

Cardiology report (ventricular report, mitral value report, aortic report, left ventricle report)

 Search

  Gray-scale 

256 gray-scale 

  Language interface 

Chinese and English available

  Function of the trackball

 Performing various operations based on the working state and menu

Controlling multiple electronic scale, locating the cursor, completing measurement

  Input/output port 

 VGA output port

DVI output port

 Network port

USB port

  Video port

Introduction to the probe

 3.5MHzR65 multi-frequency convex probe   

The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 60°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.

Scope of application: examination and diagnosis of abdominal tissues, such as liver, gallbladder, spleen, pancreas, kidneys, gastro-intestinal, uterus, urinary bladder, prostate, etc.; assessment of growth and maturity of fetus in obstetric diagnosis.  

 6.5MHzR10 multi-frequency convex probe 

The probes have a frequency range between 5.0MHz-9.0MHz. In the B-Mode , they have a scanning angle of 140-158°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.

Scope of application: vagina, uterus, rectum, rectum wall, prostata, etc.

Warning: Oil- and bacteria-free rubber sleeve must be added when using the probes. The probes should not be activated until going in the patient’s body.

  7.5MHzL46 multi-frequency linear probe

The probes have a frequency range between 6.0MHz-12.0MHz. In the B-Mode , they have a scanning width of 38-45. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.

Scope of application: newborns, musculoskeletal system, peripheral vessels, small parts (including breasts, thyroid, testis, etc.)

 3.0MHzL19 multi-frequency phased-array probe

  The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 90°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode and M-Mode.

Scope of application: heart, abdominal tissues and parts  

 4.0MHzR40 multi-frequency convex volume probe

 The probes have a frequency range between 2.0MHz-5.5MHz. In the B-Mode , they have a scanning angle of 70°. In the M-Mode, they can activate particular array element as fixed-frequency probes. They can be used in the combination of B-Mode  and M-Mode.

Scope of application: real-time 3D scan; examination and diagnosis of fetus, abdominal tissues, uterus, etc.; assessment of growth and maturity of fetus in obstetric diagnosis.

 

 

Imags of  maquina de ultrasonido 3d 4d:

 

 

 

 

 

 

 

 

 

Packaging & Shipping

dual screen ultasound machine packing details:

 

 

Delivery details:

 

Brand

DAWEI

Origin

China

MOQ

1 set

Delivery

3(THREE) working days after receiving the payment

Payment

TT,Western Union,Paypal,Escrow, L/C,Credit Sale

Package

Packed double cartons,bound with four plastic belts externally

Warranty

TWO years warranty . 

After TWO years the cost of providing paid services to maintenance

Validity

7 working days

 

 

 
Company Information

 

 

 

 

 

 

If you want to know more about our 4D ultasound machine , contact now!!

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Jiangsu, China
Chat
ManufacturerTraders
Messages