Overview
Product Details
The on grid wind turbine converter adopts AC-DC-AC PWM rectification plus PWM full-bridge inverter two-stage circuit technology. The core control adopts dual DSP full digital control, and realizes the stator magnetic field oriented vector control strategy on the rotor side converter of power generation. The grid-side converter implements the grid voltage directional vector control strategy; the system has the functions of adjustable input and output power factor, automatic soft grid connection and maximum power point tracking control. The power module uses high switching frequency IGBT power devices to ensure a good output waveform. This rectifier inverter device has the advantages of simple structure and less harmonic content.
1. Adopt PWM rectification plus PWM full-bridge inverter two-stage circuit, which can achieve the characteristics of wide output voltage range, high precision and fast dynamic response;
2. Adopt the principle of PWM rectification + PWM inverter, power factor>0.99;
3. THD and injected harmonic current meet the national standard GB/T14549-93;
4. Complete measurement functions: voltage, current, current peak, frequency, etc .;
5. Save the fault function: support historical data query, automatically record the power status and alarm code at the time of alarm, greatly reducing maintenance time;
6. Touch screen, user-friendly design, no operation for 5 minutes, automatic black screen, parameter setting requires password entry, to prevent misuse;
7. 7inch color touch screen display, operating system data, fault information at a glance, convenient parameter setting;
8. Support RS485, WiFi, GPRS, Ethernet and other communication methods. You can monitor the working status in real time through the PC or mobile phone, and you can also query the historical working status. The mobile terminal is compatible with Android and IOS. All data can be connected to the Internet of Things.
On grid wind turbine inverter |
DMWG50K |
DMWG100K |
DMWG200K |
Rated output power (AC) |
50KW |
100KW |
200KW |
Max. Output power (AC) |
55KW |
110KW |
220KW |
Input voltage rang (DC) |
0-800V |
0-800V |
0-800V |
MPPT Voltage range (DC) |
150V-700V |
150V-700V |
150V-700V |
Max. Input current (DC) |
114.6A |
229A |
458.3A |
Rated current |
104A |
208A |
416.7A |
THD Current harmonic |
<3%(at rated power) |
||
Power factor |
>0.99 |
||
Max. efficiency |
96% |
||
Allowable grid voltage range (AC) |
220V/380V/440V/480V (Three-phase)±20% |
||
Allowable grid frequency range |
50Hz/60Hz±10% |
||
Automatic operation conditions |
DC input and power grid meet the requirements, and the inverter operates automatically |
||
Restart time after power failure |
30s (adjustable) |
||
General parameters |
|||
Function |
Wind turbine curve setting |
||
Automatic protection |
Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
||
Display |
Touch screen, LCD |
||
Monitoring content |
DC input voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed |
||
Protection level |
IP20(Indoor)IP65 (Outdoors) |
||
Telematics |
RS485/USB/GPRS/WIFI/Ethernet (optional) |
||
Environment |
Operating amb. Temp. & Hum -30-60°C,<90% no condensation |
||
Noise (1m) |
<40dB |
||
Refrigeration mode |
Forced air cooling |
||
Size / weight |
|||
Inverter size / weight |
750*600*1320mm 340kg |
1460*860*1820mm 1.4t |
1460*860*1820mm 1.6t |
*Above parameter only for reference. Could be custom made to user specifications.
Generator power converter |
DMGC300K |
DMGC500K |
DMGC1000K |
Generator rated power |
300KW |
500KW |
1000KW |
Rated voltage of generator (AC) |
400V/690V |
400V/690V |
400V/690V |
Input voltage range (AC) |
0-550V/0-800V |
0-550V/0-800V |
0-550V/0-800V |
Rated output power (AC) |
300KW |
500KW |
1000KW |
MPPT MPPT Voltage range (AC) |
250-500V/400-750V |
250-500V/400-750V |
250-500V/400-750V |
Max. Input current (AC) |
476A/276A |
794A/460A |
1588A/920A |
Rated output current (AC) |
433A/251A |
722A/418A |
1444A/837A |
THD Current harmonic |
<3%(At rated power) |
||
Power factor |
>0.99 |
||
Max. efficiency |
96% |
||
Electrical structure |
Power frequency transformer |
||
Allowable grid voltage range (AC) |
220V/380V/440V/480V (Three-phase) ±20% |
||
Allowable grid frequency range |
50Hz/60Hz±10% |
||
Automatic operation conditions |
AC input and power grid meet the requirements, and the power converter operates automatically |
||
Restart time after power failure |
2min ( Adjustable) |
||
General parameters |
|||
Function |
Rectification, wind turbine curve setting, adjustable output power |
||
Automatic protection |
Reverse connection protection, short circuit protection, island effect protection, LVRT, overheat protection, overload protection, ground fault protection, lightning arrester, etc |
||
Display |
Touch screen |
||
Monitoring content |
Generator voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time |
||
Protection level |
IP20(Indoor)IP65 (Outdoors) |
||
Telematics |
RS485/USB/GPRS/WIFI/Ethernet (Optional) |
||
Environment |
Operating amb. Temp. & Hum -10-50°C,<90% no condensation |
||
Noise (1m) |
<70dB |
||
Refrigeration mode |
Forced air cooling |
||
size / weight |
2010*1060*2000mm 1.5t |
2800*1200*2000mm 2.5t |
4000*1200*2000mm 4t |
*Above parameter only for reference. Could be custom made to user specifications.
Service guarantee As our corporate users, you enjoy the following service: (1) The machine warranty for free in 2 year; (2) Technical support; (3) Within 24 hours for respond after receiving notification; (4) Cost maintenance forever. When you confirm the failure of equipment, please promptly contact us and provide the equipment model and complete description of the problem.
However, any of the following situation happened, are not included in the warranty: (1) Non-permitted by the company, went ahead with repair and damage; (2) Install or modify arbitrarily; (3) Incorrect operation or use; (4) Do not depending on the manual to do cleaning or maintenance; (5) Abnormal environment condition exceed the specifications, result in damage; (6) The deliberate destruction of man-made; (7) Irresistible natural disasters.