CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

$37.02/Stand
Place of Origin
China
Shipping
Air Freight, Ocean Freight, Land Freight

Product Description

Overview

flow
eighty-three
model
CDLF
principle
centrifugal pump
material quality
Stainless steel
voltage
three hundred and eighty
weight
seventy-eight
pressure
two
lift
seventy
Driving method
Electric
Pump shaft position
Transport medium
Clear water
Impeller structure
Number of impellers
multistage
Impeller suction method
eccentric
quantity
nine hundred and ninety-nine
performance
health
series
multistage
power
25kW
speed
three thousand
working temperature
normal temperature
brand
Galileo/Galileo

Product Details

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian
CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

Galileo - best-selling brand - European quality
1. Reliable quality, long service life 2. Stable operation, less worry 3. Considerate service, timely maintenance

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

Product Introduction: CDLF Vertical Stainless Steel Multistage Pump

The CDLF vertical stainless steel lightweight multi-stage pump is manufactured using international advanced technology, and its major advantage is the use of advanced hydraulic model design, high efficiency, and high energy conservation. The internal impeller, pump casing, and its main accessories of the water pump are formed by stainless steel stamping, and the flow channel is particularly smooth. The bearing bush and sleeve are made of hard alloy, which has a long service life and avoids secondary pollution. The shaft seal adopts wear-resistant mechanical seal, without leakage. The motor adopts an aluminum shell, imported bearings, and insulation level F. The pump operates smoothly, with low noise, reliable overall quality, beautiful appearance, small size, light weight, and convenient transportation and installation. It is an ideal green, environmentally friendly, and energy-saving water pump.

CDLF Vertical Stainless Steel Multistage Pump Model Meaning:

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian


CDLF vertical stainless steel multi-stage pump Performance range:

Flow rate: 1-22m3/h;
Lift: 6-232m;
Power: 0.37-15kw;
Speed: 2900r/m;
Caliber: φ 25- φ 50;
Temperature range: -15 ℃ -+120 ℃;

CDLF vertical stainless steel multi-stage pump Product features:

1. Adopting excellent hydraulic models and advanced manufacturing processes greatly improves the performance and service life of the pump.
2. Due to the use of mechanical seals made of hard alloy and fluororubber, the reliability of pump operation and the temperature of the conveying medium can be improved.
3. The overflow part of the pump is made of stainless steel plate stamped and welded, making it suitable for mild corrosive media.
4. The overall structure is compact, small in size, light in weight, low in noise, significantly energy-saving, and convenient for maintenance.
5. The inlet and outlet of the pump are located on the same horizontal line as the pump seat, and can be directly used in the pipeline.
6. Using standard motors, users can easily equip them according to their needs.
7. Intelligent protectors can be equipped according to user needs to effectively protect pump dry running, phase loss, overload, etc.

CDLF vertical stainless steel multi-stage pump, conveying medium:

1. A thin, clean, non flammable and explosive medium that does not contain solid particles or fibers.
2. Such as mineral water, softened water, pure water, clear oil, and other light chemical media.
3. The main material of the pump is stainless steel, which can be used to pump mild corrosive media.

CDLF Vertical Stainless Steel Multistage Pump Product Usage:

Water supply: water plant filtration and transportation, water plant zoning water supply, main pipe pressurization, and high-rise building pressurization.
Industrial pressurization: process water system, cleaning system, high-pressure flushing system, fire protection system.
Industrial liquid transportation: cooling and air conditioning systems, boiler water supply and condensation systems, machine tool support, and transportation of acidic and alkaline media.
Water treatment: ultrafiltration system, reverse osmosis system, distillation system, separator, and water treatment system for swimming pools.
Irrigation: farmland irrigation, sprinkler irrigation, drip irrigation.

Structure diagram of CDLF vertical stainless steel multi-stage pump:

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

Serial number

Component Name

Serial number

Component Name

one

electrical machinery

five

Intermediate cavity

two

frame

six

floor

three

axis

seven

Pump body

four

impeller

eight

mechanical seal





CDLF vertical stainless steel multi-stage pump performance chart:


CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian

Installation of CDLF type vertical stainless steel multi-stage pump:

1. The CDLF vertical stainless steel multi-stage pump should be installed vertically on the ground,. Ensure that sufficient cold air enters the motor cooling fan during installation. The arrow at the bottom of the pump indicates the direction of flow through the pump.
2. To minimize the possible noise generated by the pump, it is advisable to install anti vibration fixing components on both sides of the pump and between the foundation and the pump body. The mating flange, gasket, bolts, and PJE joint venture are provided as accessories and must be ordered separately. If necessary, when cleaning, repairing, or replacing the pump, isolation valves should be installed on both sides of the pump to prevent system drainage. The installation pipeline of multi-stage centrifugal pumps should avoid air blockage, especially on the suction side of the pump. The pipe should be installed in such a way that any stretching caused by temperature changes will not affect the pump. If the pump is installed on a long pipe, it should be properly supported in front and back as shown.
3. If the multi-stage centrifugal pump is at risk of being blocked by stones, leaves, small branches, etc., measures should be taken to prevent such incidents from happening. Install a filter screen on the suction tube.
4. In some installation situations, if the drainage pipe is already installed horizontally or tilted downwards by the pump, the water inside the pump will or will inevitably flow out at intervals. The pump should be protected from idle rotation of the impeller. Installing a damaged pipe with a vacuum valve near the pump can avoid this situation. The high point of the ring pipe should be at least flush with the connecting plate of the pump's motor. This way, the drainage pipe can drain water separately from the pump, and vice versa.
5. When the drain valve is closed, it is prohibited for the pump to operate, as this can cause an increase in temperature/steam formation inside the pump, leading to pump damage. If there is any danger to the operation of the pump when the drainage room is closed, connect a bypass or drain pipe to the outlet to ensure that a small amount of liquid flows through the pump. A drainage pipe, for example, can be connected to a water tank.
6. The small quantity of QDL and QDLF lightweight multi-stage pumps.

Example of CDLF vertical stainless steel multi-stage pump:

Example of a typical high-pressure scouring system diagram. Galileo Pump recommends this installation method as shown in the figure for situations where "small flow" cannot be guaranteed to pass through the pump.
1. The liquid flow switch of a lightweight multi-stage pump will provide protection to the pump from damage caused by high heat generated during pump operation when the liquid flow is too small.
2. The filter screen of a lightweight multi-stage pump is installed to protect the liquid flow switch in devices used to transport slightly polluted water.
Note: The above measures are not necessary in devices that have stable liquid flow conditions and can ensure low flow rates. In devices with water hammer hazards, a check valve must always be installed at the outlet of the pump. Do not use a quick closing valve, such as a quick closing spray gun, as this type of spray gun can cause water hammer. It affects the connection between the motor and the pump shaft, and in severe cases, it can cause the pump shaft to break.

CDLF vertical stainless steel multi-stage pump electrical connection:

1. Before opening the junction box cover and removing any pump components, the power supply of a lightweight multi-stage pump must be turned off. Electrical connections must be carried out by qualified electricians in accordance with local regulations. The motor junction box must be correctly connected to the power switch wires. The operating voltage and frequency are indicated on the nameplate. Note that the power supply used should be suitable for the motor. The three-phase motor must be connected to a starter with only a protective function.
2. The junction box of the lightweight multi-stage pump can be sequentially turned to 90 ° and stopped in four positions. When needed, a screwdriver can be used to remove the coupling guard, but do not remove the coupling. Unscrew the bolts that secure the motor to the pump. Rotate the motor to the desired position. Tighten the bolts again. Reinstall the coupling guard plate so that it is vertically centered within the recess of the pump head. Electrical connections should be made according to the wiring diagram inside the junction box cover.
Note: Do not start the light multi-stage pump before it is filled with liquid.

Start the CDLF vertical stainless steel multi-stage pump:

1、 When the liquid level of a lightweight multi-stage pump is higher than that of a closed or open system at the pump inlet:
1. Close the drainage isolation valve and loosen the exhaust screw on the pump head.
2. Please pay attention to the direction of the exhaust port and ensure that the water flowing out will not cause harm to people or damage the motor or other components. In hot water installations, special attention should be paid to the risk of burns caused by burning hot water.
3. Slowly open the isolation valve on the suction pipe until a smooth flow of liquid flows out of the exhaust valve.
4. When starting the lightweight multi-stage pump, tighten the exhaust screw and fully open the isolation valve.
2、 When the liquid level of a lightweight multi-stage pump is lower than that of the pump inlet open system:
1. The suction pipe and pump must be filled with liquid and vented before starting the pump.
2. QDL2, 4 (QDLF2, 4, 8, 16)
3. Close the drainage isolation valve. Rotate the bypass valve out slightly towards the stop, as shown in Figure 7.
4. Remove the filling plug and fill the liquid from the filling port until the suction pipe and pump are completely filled with liquid, then tighten the bypass valve again.
5. When starting the lightweight multi-stage pump, replace the filling plug and tighten it firmly.
3、 Check the rotation direction when starting a lightweight multi-stage pump:
1. Do not start the light multi-stage pump to check the direction of rotation until it is filled with liquid.
2. When checking the running direction of the motor, the coupling should not be disassembled for inspection. Because when the coupling is removed, the position of the shaft needs to be adjusted. The correct direction of rotation is indicated by the arrow on the pump head or on the motor fan cover. From the fan, the light multi-stage pump should rotate counterclockwise.
4、 Starting of lightweight vertical multi-stage pumps:
1. Before starting a lightweight multi-stage pump, fully open the isolation valve on the suction side of the pump and leave the isolation valve on the discharge side almost closed.
2. When starting a lightweight multi-stage pump, loosen the exhaust screw on the pump head to allow the pump to exhaust until a smooth flow of liquid flows out of the exhaust hole, and then tighten the exhaust screw.
Attention: The direction of the exhaust hole should be ensured, and the liquid flowing out should not cause injury to people or damage to the motor or other components. In hot water installations, special attention should be paid to the risk of burns caused by burning hot water. When the pipeline system is filled with liquid, slowly open the isolation valve until it is fully opened. When pumping liquid containing air, it is advisable to regularly exhaust the pump. To exhaust the pump, loosen the exhaust screw on the pump head during operation.

Maintenance, start and stop frequency of CDLF vertical stainless steel multi-stage pump:

Maintenance of CDLF vertical stainless steel multi-stage pump:
1. Before starting the operation of a vertical multi-stage pump, it is necessary to verify that there is no power supply to the pump and that the pump cannot suddenly start.
2. The bearings and shaft seals of lightweight multi-stage pumps do not require maintenance. If the pump needs to be drained for a long time, one of the coupling guard plates can be removed and a few drops of silicone oil can be injected into the shaft between the pump head and the coupling. This can prevent the shaft sealing surface from sticking.
3. When installing the coupling guard plates, be sure to align them vertically in the recess of the pump head.
CDLF vertical stainless steel multi-stage pump motor bearing:
4. For motors without lubrication nozzles, maintenance is not required. Motors equipped with lubrication nozzles should be lubricated with high-temperature lithium based grease.
5. If the light multi-stage pump is temporarily suspended for a long time, it is recommended to clean and lubricate the pump and motor once they are not in use.
6. During the frost period, the pump should be left unused and the water should be drained to prevent damage and cracking. Loosen the exhaust screw on the pump head and remove the drain plug on the base to drain the pump. After the water is drained, the removed components should be reinstalled in place or properly stored.
Starting and stopping frequency of CDLF vertical stainless steel multi-stage pump:
Electric motors with a power of less than 4KW for vertical multi-stage pumps shall not exceed 100 starts per hour. The number of starts for other motors shall not exceed 20 per hour.

Declaration: Due to the continuous updating of the product, all text, data, and images in this article are only for reference. The performance parameters of CDLF vertical stainless steel multi-stage pump, the usage scenarios of CDLF vertical stainless steel multi-stage pump, the material requirements of CDLF vertical stainless steel multi-stage pump, the structure of CDLF vertical stainless steel multi-stage pump, the installation dimensions of CDLF vertical stainless steel multi-stage pump, and the price of CDLF vertical stainless steel multi-stage pump are detailed, We will definitely do our best to provide you with services.

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump DianCDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>

Wooden case, foam or carton packaging, because this pump belongs to heavy goods, it can only be delivered to the logistics station (it needs to be picked up by the logistics station). Please contact us with other questions.

CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>

After sales service commitment

1. The product provides free maintenance for one year. During the free maintenance period, if there is any damage caused by non human factors (excluding force majeure reasons), Shanghai Cangmao Industry will promptly replace and repair it for free.

2. The product is guaranteed for lifetime repair. If the buyer entrusts Shanghai Cangmao Industry for maintenance and upkeep after the free warranty period expires, Shanghai Cangmao Industry will maintain and replace the equipment with replacement parts, and provide detailed maintenance content.

3. Shanghai Cangmao Industry adheres to the principle of putting customer interests first, thinking about what customers think and being urgent, and doing its best to meet customer requirements and provide good after-sales service.

Product Quality Commitment

1. Shanghai Cangmao Industry is responsible for the quality and delivery time of the products. The warranty period from the date of product delivery is one year (three months for vulnerable parts), with lifelong maintenance. Shanghai Cangmao Industry shall bear corresponding responsibilities for the consequences caused by product quality. If the consequences are caused by improper operation, Shanghai Cangmao Industry will maintain the equipment at a low cost.

2. Conduct inspections and evaluations on all sub suppliers, and purchase all products only from qualified sub suppliers. The raw materials, purchased parts, and outsourced parts provided by the sub suppliers must undergo strict review and inspection before being allowed to enter the warehouse;

3. The product manufacturing strictly implements the "double three inspections" system, and unqualified parts are not transferred, assembled, or left the factory;


CDL stainless steel stamping center opening FB centrifugal pipeline variable frequency pressurized vertical multi-stage pump Dian</imgoverload>

Trading Area

Global

Quotation

Name
Company
Phone
Email Address
Requirements
Quotation
Shanghai, China
Chat
ManufacturerTraders
Messages